I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. Refer to the wiring diagram on the timer door for more information. Hi Rhomell, are you sure you got the correct trippers? My intermatic timer is about two years old as well. Tighten down all brass screws securely, to hold all wires firmly in place. Today is the second day that I have had to turn it on manually. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. The yellow clock face should sit down in the timer. I think I have found it. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. Are the gears engaged, in the center, behind the dial? ), you should be able to discern if this is the problem, which could mean a new clock. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. Pool timer malfunction - DoItYourself.com Community Forums The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . If power is coming to the timer motor, you will clearly see the gears moving through the small window. Elite. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). March 16, 2022 by WildRiverCountry. It is still moving and it will trip off but not on. I currently manually turn it on and off. }
. It should sit down nicely. For additional tripper pairs on CLOCK-DIALorder 156T1978A. "address": "",
When I put the new one on, the trippers do not work. You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. Slide it around the pool timer dial to the correct start time and re-tighten it. Back when I was a young technician I was taught to always look for the easy things and use all my senses. Grab your torch and shine it in the holes. Gold OFF tripper works for all models. If you loosen the hold down screw to much it could separate from the timer pin. Above you said to connect white to A. and Black to 1what do I do with red? What is the problem? To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. You can check these easily by removing them and inspecting them for damage. Hello, newer pool guy here. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. To do this, pull the yellow-faced time dial (clockface) toward you. Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. Or other advice or explanation. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. You can have as many ON an OFF trippes as you want. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Trippers are not installed properly Re-install trippers on dial 2. I believe its the manual on/off switch that is the problem. Ive got the opposite problem than a lot of people. The 12 Best Pool Timers of 2022 - WildRiver The old "off" tripper was fractionally bent. "@type": "ImageObject",
I fastened it very securely. I dont see timer gears rotating on any power going to the pump or salt system. There are many reasons why your pool timer may not be working. First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. Sometimes during power surges or lightning, these will be fused together and not come apart. Garden Guides | How to Troubleshoot a Swimming Pool Timer Thank you. Is it Necessary? Just above the yellow clock youll see some holes. "url": "https://blog.intheswim.com/"
You should always be able to switch your pump on and off manually at the timer. If you are not sure if your timer is working or not you will first need to know if its even operational. Hello. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. If the pump comes on, you definitely have power to the timer. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Or be loose and not making good contact. Some white lithium grease on the switch can help in some cases. Flip it from where it is now, to the opposite side. Hi Sandra, does the on/off tab switch crisply, or softly? After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. Thanks. Replace them if they appear to be bent. Gently tighten the screws to securely hold the dogs in place. You can also apply some of the troubleshooting steps to other brand timers. Push the tab on the top, and let the mechanism fall forward. do i need to do something different? If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . Perhaps you had a power outage during the night? Any other thoughts? For Sale: 2 beds, 2 baths 1152 sq. Thank you so much. Is power reaching the time clock? },
2,767 Sq. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. If its loose, grab a screwdriver and tighten it up. Articles and resources for swimming pool owners and DIYers. Read Book Tork Trippers Manual Guide Pdf For Free - twiki.skotos The capacitor for the motor may be bad. "caption": "In The Swim Blog"
Only perform this step if you are qualified. Does the manual lever stay in the on position always? Clock wont move, gear dont move at all. My pump has a plug. I have Model T40004RTe. Flip off the breaker. A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. "primaryImageOfPage": {
Hi Rich, is one of those wires (white?) All Rights Reserved. Is it keeping time normally? Just installed a new timer. Just some ideas. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Types of Pool Timers & How They Work - Pool Research The clock is powered from the Line 1 terminal correct? Leave the paper inside your timer box so that you do not mistakenly misplace it. What happened? please help me. If so, is there power coming into the clock (on the line terminals)? At some time the timer was disconnected and the pump wired direct to the breakers. The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. Not sure if you still answer these but I have a weird one for you. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. Stupid third question, but does the ON tripper say ON? the trippers are even slightly damaged the timer won't work correctly. 975 Telegraph Rd #103, Santa Paula, CA 93060 | MLS# V1-15365 | Redfin Is the ON tripper all the way pushed onto the dial? Why do we stock so many pool parts? I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. Look for any disconnected or damaged wires leading to the motor on the rear of the clock. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. Partially loosen the screw that holds the "off" pin in place. Reasons Why Pool Timers Stop Working 1. Hello Davy, Terry here again. I am using the breaker to turn on and off the pool pump. Hi Bob, you have two blacks and one neutral? "@context": "https://schema.org/",
It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. Wired correctly, #10 wire, nothing. Was a good island when all the day trippers left My timer clock does not run and the manual on off switch does not turn off the pump motor. Clock not turning or making any sound. . Take them off and inspect them and look for twists in them. Second thing to check is the dial bent or warped, in that area where the on tripper is? South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveler reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. Until it came in, I manually turned on and the tripper turned it off. They are little ants that just came. Any suggestions? It loses about 1.5 to 2 hours per day without any outages. It is not warped in any way. There should be an off pin and an on pin. Sometimes those are looped back to the control box. Rich. Tork Pool Timer does not trip on - JustAnswer If its not, then the timer will not turn on/off at the correct times. I have replaced the trippers, but the problem persists. Intermatic Pool Timer Troubleshooting & Repair Guide - WeT HeaD Media Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. The pump worked perfectly before I unscrewed it. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. My pool pump and skimmer are on two different motors. Breakers go bad sometimes, after many years. Then remove the mechanism by pressing the clip at the top of the timer box. Off flipper always works. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! },
sometimes Im forgetful lol what are your thoughts? To set it, you just move the on/off "trippers" where you want them. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. Inspect the tripper portion, if it looks rounder or worn, replace them. MLS # 6354744 how should I lubricate those? I am having the same problem. Can I wire this timer to an outlet or should I search for another solution? Start with the easy checks. "caption": "In The Swim Blog"
Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. Tighten them with a wrench. 1. I have a sweeper set on auto on the second timer and it is working correctly. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. This will disengage the dial and allow you to spin it in either direction. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . You need extreme care in this next step. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Does the tripper work on other areas of the clock, like near the off tripper? I guess if they look the same as before maybe the dial is warped? Does the tripper work on other areas of the clock, like near the off tripper? Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. The 2,810 sq. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. PDF Model: T104 24 Hour Dial Time Switch charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. I had a thunderstorm last night and my power went off for like 3 hours. VIDEO TOUR. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. "name": "Davy Merino",
Required fields are marked *. Intermatic t101 timer troubleshooting - Ask Me Help Desk Why is my water heater timer not working? - Quick-Advices Motor runs past the on dog but doesnt flip pump on? I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. However, intermittently after the ON tripper switches pump on the pump will stop. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. Copyright 2022 In The Swim. You off course will want to adjust one time pin at a time. That will do it. If you use our referring links, it costs you nothing extra. You will have live wires exposed and they can kill you if you touch them. I bought a new motor for mine after 20 years and learned about this the hard way. The other gears move very slowly, and appear to not move at all, except for one I believe? I just replaced my T101 timer 2 years ago. Hi. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. The mechanism for the off tripper doesn't work at all when manually depressed. Or might find something else. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. You can find this in your power board. Pool Timer Clock Parts and Trippers TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. After a power failure the timer clock can start up backwards, mine has done this several times. However the new breaker is in a constantly tripped position. If you look closely (with a flashlight and your glasses! With the breakers turned off, remove the mechanism from the box. A timer that switches on and off at the wrong times usually occurs after a power outage. screwfindinganame on June 18, 2013 at 11:36 pm Here are some pictures. Is there a separate switch somewhere between breaker and timer? However, after several hours, maybe overnight, the associated breaker will trip. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. 1100 Juanita St, Austin, TX 78704 | MLS #6354744 | Zillow No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. First time pool owner, Pool timer and trippers not working properly! Intermatic T100 Series Replacement Trippers for Timers 156T1978A - The I see a little groove worn in the corner of the on/off switch where the off timer dog touches. How about the GFCI outlet TEST button, is it tripped? If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. Turn the metal bar until it contacts one of two plastic side tabs. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). The timer not working is for the pump. Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. Intermatic Pool Timer, tips & troubleshooting - YouTube The most common pool timer used for inground pool pumps is the Intermatic time clock. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. Once you have confirmed that you timer is working you will need to adjust the timer pins to reflect the time you want your filter system to turn on and off. Thanks in advance! I have a 2 speed pump. We may earn a small commission. The problem lies where the power dies, youve probably heard that before. Morgan Burley I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. 12 Best Pool Pump Timers For Reducing Your Power Bill! Pool Timer Not Turning ON or OFF!! There is a second switch between the breaker and the timer. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. The on/off pins are tight and pretty new stillany thoughts? The rest of your setup is probably fine. Ask Your Own Pool and Spa Question Ive seen it happen from lightning strikes, or insect infestation. First, verify the power is turned off at the breaker panel. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. 3. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. Or is there anything else I can check? Grab it, pull it towards you, move it around then place it back down. A power surge may have taken out the timer or the pump. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Hi, then the power for the clock must be from the switch, and not from the breaker? "logo": {
Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. BUILT BY HAND IN QUEENS, NYC. Any suggestions on how to troubleshoot? The tripper will not move. When I turned it back on now the pool clock goes backwards. Or one of the wires may have broken, or lost the protective plastic insulation. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. I have a inground pool with T10003RT4 control panel. 3 Baths. 9 Problems with Intermatic Timers and How to Fix Them - My Perfect Pool what causes timer on/off pins to bend and how can i prevent timer pins from bending. How do you know if your pool timer is bad? I also dont see any ants or other insects. Almost like it doesnt have the strength to click the timer on or off. This morning the customer said it wasn't turning off. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. If the pump doesnt come on, follow the steps below. Phil. "width": "611",
Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. Black goes to _1 I used to run the pump for 8-9 hrs a day. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. "url": "https://intheswim.com/",
Should it still not work, I suspect a motor failure for the clock. Then after a bit, the pump restarts. Did you try to flip the switch of the timeclock? Reset the clock to the correct time. Thanks again for your help. Thank you for choosing Intermatic! Watch these tips and tricks before replacing it. And Ive noticed lately that the ON is not functioning all the time. 4 Beds. This will disengage the dial from the . It I set the timer again it will jeep time until it gets to the next dog ear. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Reset the clock on the timer to the correct time to get it back to the desired on/off times. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. I just replaced an Intermatic WG1573-10D timer motor. "dateModified": "1/10/2020",
Tork timer not keeping time | Mike Holt's Forum The back of the timer dog has a tab that flips the switch, check the alignment of both, the dog may not be contacting the switch with enough surface to flip it on? These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. Intermatic timer won't turn on/off pump. | Trouble Free Pool Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. Your email address will not be published. You can turn off Freeze protection and it should stop, or replace the probe if faulty. the ground wire? Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. Hi Doug, Check the wiring. Hello. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . by Intermatic Technical Support | Jul 25, 2022 Helpful? GFCI breakers trip at a very low threshold, doesnt take much.